Search Contract Opportunities

Safety Air Monitoring and Analytical Referee System (SAMARS) Gas Chromatograph (GC)   2

ID: W911S6-24-Q-0034 • Type: Award Notice

Description

Procure two GC instruments with the following specifications:

    • Flame Photometric Detector (FPD); one instrument with phosphorous optical filter, one instrument with sulfur optical filter
    • Chromatographic columns: one instrument DB-1701 phase and one instrument DB-210 phase column;
    • Air sampling pre-concentrator trap capability with flow rate through the trap of at least 500 mL/min
    • External mass flow controller, ability to capture the flow meter readings
    • Oven programmable from ambient to 400 C
    • Cycle time from injection to injection of 15 minutes or less
    • Visible and audible alarms for system faults and sample concentration detections
    • Quick change trap assembly, flow rate of 500 mL/min with ability to change the preconcentrator tube in approximately 1 minute
    • Onboard integration engine with graphical use interface. Ability to operate the instrument, calibrate, troubleshoot, analyze samples, etc. from the user interface. Visual readouts displayed of set points and measurements such as: sample flow, temperatures, pressures, concentrations, injection types, valve status, voltage, etc.
    • Data logging. Ability to capture instrument set points and measured values such as: flow, temperatures, pressures, calibration, concentration, injection type calibration, service, sample, etc. Data captured locally with the ability to retrieve and use for other reporting or calculating of sample data.
    • Automatic calibration feature. Calibration of the instrument using an averaged single point or multi-point calibration curve. Capable of calibrating and obtaining sample concentrations using the onboard integration engine, and values displayed on the graphical user interface.
    • Heated exhaust to prevent expulsion of water. Detector exhaust must expel water in gas/vapor form elimination water drip from the instrument detector.
    • Sample bypass capability. Ability for continuous sample flow at inlet in a bypass state. A minimum flow of 500 mL/min required for bypass capability.
    • GC approximate dimensions - 17 x 11 x 8.5 (width x height x depth)
    • Instrument weight approximately 25 pounds

Overview

Award ID
W911S625P0002
Reported Award
$228,674
Award Date
March 24, 2025
Posted
April 8, 2025, 12:29 p.m. EDT
Set Aside
None
Place of Performance
Dugway, UT 84022 United States
Source
SAM

Current SBA Size Standard
1000 Employees
Pricing
Likely Fixed Price
Safety Air Monitoring and Analytical Referee System (SAMARS) Gas Chromatograph (GC) (W911S6-24-Q-0034) was awarded to Teledyne Instruments on 4/8/25 by MICC Dugway Proving Ground.
Primary Contact
Name
Nneka Okeke-Stubbs   Profile
Phone
(435) 831-2748

Secondary Contact

Name
Paul E. Frailey   Profile
Phone
(435) 831-2587

Documents

Posted documents for Award Notice W911S6-24-Q-0034

Question & Answer

Opportunity Lifecycle

Procurement notices related to Award Notice W911S6-24-Q-0034

Award Notifications

Agency published notification of awards for Award Notice W911S6-24-Q-0034

Similar Active Opportunities

Open contract opportunities similar to Award Notice W911S6-24-Q-0034

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > AMC > ACC > MISSION & INSTALLATION CONTRACTING COMMAND > 418TH CSB
FPDS Organization Code
2100-W911S6
Source Organization Code
500036820
Last Updated
April 8, 2025
Last Updated By
nneka.okeke-stubbs.civ@army.mil
Archive Date
April 8, 2025