Search Contract Opportunities

Heat Pump   2

ID: W913E525Q0006 • Type: Synopsis Solicitation

Description

This combined synopsis/solicitation for commercial items prepared in accordance with the format at FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested.

The solicitation number W913E525Q0006 is being issued as a request for quotation (RFQ). This requirement is a total set-aside for small business concerns.

The associated North American Industry Classification System (NAICS) code is 333415 Air-Condition and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing, which has a small business size standard of 1,250 employees.

The U.S. Army Engineer Research and Development Center (ERDC), Cold Regions Research and Engineering Laboratory (CRREL)'s Office of Technical Directors in Alaska has a requirement for delivery and installation of one (1) 12,000 BTU air-to-air mini split ductless heat pump on an insulated container building at the CRREL Farmers Loop site in Fairbanks, Alaska.

Please review the attached Request for Quote for the detailed Description of Requirement (DOR), quote submission instructions, and applicable provisions & clauses.

Award will be made to the responsible offeror whose offer represents the Best Value to the Government, in consideration of all factors. The basis for award will be an acceptable proposal, the price of which may not be the lowest. The Government's determination of what represents the best value for this requirement shall be based on the following evaluation factors:

  1. Technical capability to provide the requested supply and services as outlined in Section C, Description of Requirement to include the following requirements: (a) Location Requirement: Vendor must be in the Fairbanks, AK service area due to severe winter and permafrost work conditions. (b) Certification Requirement: EPA 608 Type II Certification. Proof is required with quotations. (c) Schedule Requirement: Must be able to complete heat pump installation by 28 February 2025.
  2. Total quoted price to fulfill the Government's requirement in its entirety to include all shipping costs to CRREL Farmers Loop, 286 Farmers Loop Road, Fairbanks, AK 99712.

Payment Terms: Net 30

Please provide responses to this notice, no later than Tuesday, 21 January 2025, 12:00 PM, Central Standard Time (CST) to:

ERDC-CRREL-QUOTES@usace.army.mil

Telephone responses will not be accepted.

*Note: To be eligible for award of a Government contract, vendors must be actively registered in the System for Award Management (SAM), have no active exclusions, and complete representations and certifications. For more information, review the SAM website at https://www.sam.gov.

Background
The U.S. Army Engineer Research and Development Center (ERDC), Cold Regions Research and Engineering Laboratory (CRREL) in Alaska has a requirement for the delivery and installation of a heat pump. This contract is aimed at providing heating solutions suitable for severe winter conditions and permafrost, aligning with the agency's mission to support engineering research and development in cold regions.

Work Details
The contractor shall deliver and install one (1) 12,000 BTU air-to-air mini split ductless heat pump on an insulated container building at the CRREL Farmers Loop site in Fairbanks, Alaska. The specifications for the heat pump include:
- Air-to-air
- Ductless (mini split)
- Single zone
- 12,000 BTU rated output
- Capability to provide heat down to -13°F
- Insulated and covered refrigerant lines
- Heated condensate drain line.

The installation will occur on an 8x20 ft insulated container building with the indoor unit inside and the outdoor component outside. Additionally, the contractor must ensure that all shipping costs are included in their total quoted price to deliver the items to CRREL Farmers Loop, Fairbanks, AK 99712.

Period of Performance
The installation of the heat pump must be completed by 28 February 2025.

Place of Performance
CRREL Farmers Loop, 286 Farmers Loop Road, Fairbanks, AK 99712.

Overview

Response Deadline
Jan. 21, 2025, 1:00 p.m. EST Past Due
Posted
Jan. 8, 2025, 11:52 a.m. EST
Set Aside
Small Business (SBA)
Place of Performance
Fairbanks, AK 99712 United States
Source
SAM

Current SBA Size Standard
1250 Employees
Pricing
Likely Fixed Price
Evaluation Criteria
Best Value
Est. Level of Competition
Average
On 1/8/25 Engineer Research and Development Center issued Synopsis Solicitation W913E525Q0006 for Heat Pump due 1/21/25. The opportunity was issued with a Small Business (SBA) set aside with NAICS 333415 (SBA Size Standard 1250 Employees) and PSC 6685.
Primary Contact
Name
ERDC-CRREL Quotes   Profile
Phone
None

Documents

Posted documents for Synopsis Solicitation W913E525Q0006

Question & Answer

Opportunity Lifecycle

Procurement notices related to Synopsis Solicitation W913E525Q0006

Award Notifications

Agency published notification of awards for Synopsis Solicitation W913E525Q0006

Incumbent or Similar Awards

Potential Bidders and Partners

Awardees that have won contracts similar to Synopsis Solicitation W913E525Q0006

Similar Active Opportunities

Open contract opportunities similar to Synopsis Solicitation W913E525Q0006

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > USACE > OTHER DIVISION > W2R2 COLD RGNS RSCH ENG LAB
FPDS Organization Code
2100-W913E5
Source Organization Code
100221792
Last Updated
Feb. 5, 2025
Last Updated By
latosha.n.rodgers@usace.army.mil
Archive Date
Feb. 5, 2025